E+/E- excite the bridge, and A+/A- read its differential output. The optional shield is separate from the bridge. Wire colors vary, so confirm them against the sensor documentation.
VCC and VDD
VCC powers the analog circuit; VDD sets the digital interface voltage. They can share a supply when it matches the host logic, or use different voltages within the documented limits.
Channel and gain
Channel A offers gains 128 or 64; channel B uses gain 32. Channel and gain are selected by the number of serial clock pulses.
Conversion rate
The RATE solder jumper is closed by default for 10 samples per second. Opening it selects 80 samples per second, with more noise per reading.
Calibration
Tare the unloaded scale and calibrate with a known weight. ADC output width does not by itself guarantee 24-bit measurement accuracy.